LoggFi Logo

LoggFi temperature monitoring · India

Temperature data loggers in India

Compare WiFi and GSM temperature data loggers for refrigerators, cold rooms, laboratories and industrial monitoring. Choose by probe range, connectivity and calibration requirements.

A temperature data logger, also called a temperature logger, automatically records temperature at set intervals. Unlike a thermometer that shows the current reading, it keeps a history for review. LoggFi connected loggers send readings to a cloud dashboard for remote monitoring when a network connection is available.

Explore LoggFi models from Bagmo Private Limited in Kochi, Kerala, for facilities across India.

Compare temperature data logger models

Start with your application and connection. These display models are a starting shortlist; compact, GSM, and local-siren alternatives are available in the complete catalogue.

Scroll the comparison table horizontally to see all specifications.

LoggFi temperature data logger specifications at a glance
ModelConnectionProbe rangeListed temperature accuracyOffline readings
WTD102WiFi−40°C to +50°C±0.5°C2,000
SMD102GSM/GPRS (2G)−40°C to +50°C±0.5°C500
WTD102PTWiFi−200°C to +400°C±0.5°C2,000
WTD102HMWiFi−40°C to +50°C±0.5°C2,000

Listed accuracy must be confirmed at your working temperatures. Probe range is separate from the electronics’ operating limits; offline storage requires power. Model details and quotation links follow below.

LoggFi WiFi logger — catalogue product image
Catalogue image · LoggFi family

WiFi · OLED display

WTD102

Refrigerators and cold rooms with facility WiFi

An NTC temperature logger with an OLED display for fixed monitoring points with suitable wireless coverage.

Probe range
−40°C to +50°C
Listed temperature accuracy
±0.5°C
Sensor
NTC
Offline capacity
2,000 readings
LoggFi GSM logger — catalogue product image
Catalogue image · LoggFi family

GSM · OLED display

SMD102

Temperature monitoring where WiFi is unavailable

An NTC temperature logger with an OLED display and a SIM-based connection. Confirm compatible GSM/GPRS (2G) service on site.

Probe range
−40°C to +50°C
Listed temperature accuracy
±0.5°C
Sensor
NTC
Offline capacity
500 readings
LoggFi+ PT100 WiFi logger — catalogue product image
Catalogue image · LoggFi+ PT100 family

WiFi · OLED display

WTD102PT

Processes that need a wider probe temperature range

A WiFi PT100 model with an OLED display. Select the probe assembly for the temperature, mounting and conditions of your process.

Probe range
−200°C to +400°C
Listed temperature accuracy
±0.5°C
Sensor
PT-100
Offline capacity
2,000 readings
LoggFi Hygro WiFi logger — catalogue product image
Catalogue image · LoggFi Hygro family

WiFi · OLED display

WTD102HM

Rooms that need temperature and humidity records

A WiFi model with an OLED display and NTC / SHT20 sensing. The catalogue lists 0–90% RH; request humidity accuracy separately.

Probe range
−40°C to +50°C
Listed temperature accuracy
±0.5°C
Sensor
NTC & SHT20
Offline capacity
2,000 readings

Specifications are from the LoggFi catalogue. Probe range is separate from the electronics’ operating limits. Confirm accuracy at your working temperatures, the supplied probe and calibration scope. Offline recording requires power; capacity is not battery runtime.

Choose calibration and service with your logger

The catalogue lists internal / NABL calibration options. Tell us your required calibration points and certificate requirements so the quotation can identify the supplied device and probe, certificate scope and calibration charges.

Pricing is configuration-specific. Ask for hardware, calibration, installation, cloud access, alert charges and renewals as separate line items, including taxes and written warranty terms.

How real-time temperature monitoring works

A connected data logger lets your team review readings remotely as they reach the cloud. To choose a real-time data logger, compare the recording interval, upload frequency and alert delivery time separately.

  1. Record a reading

    The probe measures temperature and the logger records readings at the configured logging interval.

  2. Upload through the network

    The logger sends readings through facility WiFi or a compatible SIM-based GSM connection.

  3. Review the dashboard

    Your team views uploaded readings and temperature history through the cloud platform. Check the reading timestamp when assessing current conditions.

  4. Receive a configured alert

    Remote notifications help the responsible person respond to an out-of-range condition. Delivery depends on connectivity and the configured alert service.

How quickly will I see a reading or alert?

Recording interval
Catalogue setting: 1 – 40 minutes. This describes recording frequency, not a guaranteed dashboard refresh or alert time.
Upload frequency
Confirm the upload configuration for your chosen model. A measured end-to-end upload time is not published here.
Alert delivery
Ask for a demonstration with your thresholds, recipients and notification channels. No measured delivery-time guarantee is published here.

What happens when the connection fails?

Listed WiFi temperature models store up to 2,000 offline readings; GSM temperature models store up to 500 while powered. New cloud readings and remote temperature alerts need a working connection. A last uploaded reading cannot establish the current temperature during an outage.

Before commissioning, confirm the full-buffer policy, how stored readings upload after reconnection, and any local alarm operation. Test power backup separately from network recovery.

Estimate offline storage duration

What to check in a monitoring demonstration

Ask the team to record the time of a controlled temperature change, the corresponding reading timestamp, when it appears in the dashboard, and when each recipient receives the alert. Repeat a network-disconnection and recovery test. Use these observed results to agree the setup your facility needs.

What is the best temperature data logger for your application?

The best fit meets your required measurement range and accuracy, has calibration evidence at the temperatures you use, and can record and alert reliably at your installation. Choose WiFi where facility internet is dependable, or a compatible GSM logger where you need a connection independent of WiFi. Then compare outage handling and the full cost of ownership.

This LoggFi selection guide compares our configurations using the published catalogue. It is not a ranking based on independent tests of competing brands. Request a demonstration and the supplied model's specification before ordering.

Laboratory refrigerator or cold room

Temperature monitoring within the NTC range. Catalogue range: −40°C to +50°C; listed temperature accuracy: ±0.5°C.

Confirm accuracy and calibration at your actual storage temperatures, probe placement and closed-door signal coverage.

A process outside the NTC temperature range

A PT100 probe selected for the process. Catalogue range: −200°C to +400°C; listed temperature accuracy: ±0.5°C.

Specify the complete probe assembly, cable, immersion depth and calibration points. Mount the electronics within their separate operating limits.

A room that needs temperature and humidity records

Combined temperature and relative-humidity monitoring. Catalogue range: −40°C to +50°C; listed temperature accuracy: ±0.5°C.

Request the humidity accuracy and calibration specification; a humidity range alone does not establish accuracy.

A site needing an audible local warning

A temperature logger with a local siren option. Catalogue range: −40°C to +50°C; listed temperature accuracy: ±0.5°C.

Confirm siren operation, power requirements and alert behaviour during a network outage in a site demonstration.

Scroll the table horizontally to compare both connections.

WiFi vs GSM: practical buying differences for LoggFi temperature models
DecisionWiFi modelsGSM models
ConnectionFacility WiFi and working internet; confirm band and authentication supportSIM-based GSM/GPRS (2G); confirm compatible operator service at the site
Offline capacity2,000 readings500 readings
Storage at 5-minute intervalsApproximately 166.7 hoursApproximately 41.7 hours
Recurring connectivity costsExisting internet and any network maintenanceSIM activation, data plan and renewals
Remote alerts during a network outageDepend on restoring connectivity; confirm local alarm optionsDepend on cellular connectivity; confirm local alarm options
Before orderingTest the actual installation with the IT teamTest a compatible SIM in the logger at the installation

Storage examples assume an empty buffer, continuous power and one reading per interval. They do not describe battery life. The catalogue lists typical battery backup of 20–30 hours.

Compare the complete quotation, including warranty

Compare hardware and probes, installation, calibration and recalibration, cloud access, retention and exports, alert charges, SIM/data where needed, taxes and service. Agree the period you want to compare, such as three years, and ask every supplier to itemise the same items. Published model information does not include a fixed price or warranty duration; request written warranty terms, exclusions and repair arrangements with your quote.

Get help choosing a temperature logger

WiFi or GSM: which connection fits?

Choose a connected temperature logger when your team needs to review readings remotely while monitoring continues. A standalone USB logger may suit a job where someone retrieves the device and downloads its stored record afterward. Compare the required reporting workflow before choosing the connection.

WiFi data logger

For fixed monitoring points with reliable facility WiFi and internet access. LoggFi WiFi temperature models store 2,000 offline readings. Check coverage beside the equipment and agree network access with your IT team.

View WiFi models and specifications

GSM data logger

For installations that need a SIM-based connection independent of facility WiFi. LoggFi GSM temperature models store 500 offline readings. The listed devices use GSM/GPRS (2G); verify operator coverage and service before purchase.

View GSM models and specifications

The LoggFi models on this page use WiFi or GSM for cloud connectivity. The catalogue’s 5V USB specification describes power input / charging; it does not establish USB data export or automatic PDF reporting.

Choose the sensor for your temperature range

LoggFi sensor options
Logger familySensorTemperature rangeListed accuracy
LoggFiNTC−40°C to +50°C±0.5°C
LoggFi+ PT100PT-100−200°C to +400°C±0.5°C
LoggFi HygroNTC & SHT20−40°C to +50°C±0.5°C

Hygro adds humidity monitoring from 0–90% RH. A wider probe range does not mean the logger electronics can operate at those temperatures: the catalogue lists an electronics operating environment of 10–40°C and 30–70% RH. Confirm probe suitability, placement and accuracy at your actual working temperatures.

Match the installation to the application

Cold rooms and food storage
Check the full storage temperature range, door-opening patterns and connectivity around insulated walls. Choose probe positions that represent the stock being monitored.
Hospitals, laboratories and blood storage
Define the equipment’s required limits, escalation contacts and record-retention needs. Specify calibration points and documentation with the team responsible for quality.
Pharmaceutical warehouses
Decide whether temperature alone or temperature and humidity must be monitored. Use the facility’s mapping and procedures to determine how many monitoring points are needed.
Industrial and low-temperature monitoring
Consider a PT100 model when the NTC range does not cover the process. Confirm the probe assembly and installation are suitable for the intended conditions.

Logging intervals, outages and alerts

The catalogue lists configurable logging intervals from 1 to 40 minutes. At a five-minute interval, 2,000 readings cover approximately 6.9 days, while 500 readings cover approximately 41.7 hours. These figures describe storage capacity, assuming the device remains powered; they are not battery-runtime figures.

Typical battery backup is listed as 20–30 hours. Remote notifications depend on connectivity, power and the configured service. Confirm what happens during an outage, how stored readings are uploaded afterward and whether an on-site siren is needed.

Offline storage calculator

Estimate how much time the listed LoggFi temperature logger memory covers at your logging interval. This assumes an empty buffer, continuous power and one stored reading per interval.

Enter a whole number from 1 to 40.

166.7 hours (approximately 6.9 days)

2,000 readings × 5 minutes ÷ 60 = storage duration in hours.

Storage capacity does not extend battery life. The catalogue lists typical battery backup of 20–30 hours. Cloud updates and remote alerts need a connection; confirm overwrite and reconnection behaviour for the supplied model.

Temperature history

Unlimited cloud storage for up to 3 years

LoggFi stores an unlimited number of uploaded temperature readings in the cloud for up to three years. Your team can review the temperature history of each monitored refrigerator, freezer or cold room, whether it uses a WiFi data logger or a GSM data logger.

When investigating a temperature change, you can check when the first reading crossed the configured limit, how high or low the recorded temperature went, and when readings returned to the required range.

Cloud history retained for

Up to 3 years

Unlimited uploaded readings for each monitored location.

Alerts and team response

Temperature and device-offline notifications

What triggers an alert?

  • High temperature

    The data logger records a temperature above the upper limit set for the equipment.

  • Low temperature

    The data logger records a temperature below the lower limit set for the equipment.

  • Device offline

    The logger stops sending readings to the cloud. This alerts staff to check the logger’s power and WiFi or GSM connection and verify the current equipment temperature on site.

How does your team receive notifications?

Choose the channels that suit the people responsible for each location and shift.

  • Phone call

    Draw the on-duty operator’s attention to an urgent alert, including after hours.

  • WhatsApp

    Deliver an alert directly to the designated contact on WhatsApp.

  • SMS

    Send a text alert to the responsible staff member’s mobile number.

  • Email

    Send an alert to a supervisor’s inbox or a shared quality-team mailbox.

  • Mobile app notification

    Prompt staff to open the LoggFi app and check the latest uploaded reading for the affected equipment.

Who responds at each level?

A facility can use the following alert escalation hierarchy to assign responsibility across shifts.

Scroll the table horizontally to see each role and response.

Suggested facility alert escalation hierarchy: responsible people and response actions
LevelResponsible personWhen and how to respond
1. Initial responseOn-duty operatorCheck the equipment when the alert arrives. Verify the temperature on site and investigate the cause.
2. EscalationShift supervisorFollow up if the operator is unavailable or the issue continues beyond the facility’s agreed response time. Coordinate with maintenance or IT as needed.
3. Incident reviewQuality manager or facility headReview prolonged or repeated incidents, assess the impact on stored material and document the action taken.
Remote monitoring

Check temperature readings from anywhere with the LoggFi mobile app

The LoggFi mobile app lets your team check the latest uploaded temperature and review earlier readings from anywhere with an internet connection.

Example: an overnight freezer alert

For example, if a freezer sends a high-temperature alert overnight, the shift supervisor can open the app, check the time and value of the latest reading, and review how the temperature changed. After the on-site team responds, the supervisor can check subsequent readings to see whether the freezer has returned to its required range. If the logger is offline, the timestamp shows when it last reported.

Discuss your monitoring and alert setup

What to include in a quotation request

  • Facility location in India, equipment type and number of monitoring points.
  • Required temperature range, humidity needs and probe placement.
  • WiFi access or compatible GSM service at each location.
  • Display, local alarm, remote alert recipients and reporting requirements.
  • Calibration points, certificate requirements and installation support.

Ask for hardware, cloud service, SIM/data, calibration, installation and taxes to be itemised. The catalogue lists internal / NABL calibration options; confirm the certificate and scope supplied with your order.