LoggFi temperature monitoring · India
Temperature data loggers in India
Compare WiFi and GSM temperature data loggers for refrigerators, cold rooms, laboratories and industrial monitoring. Choose by probe range, connectivity and calibration requirements.
A temperature data logger, also called a temperature logger, automatically records temperature at set intervals. Unlike a thermometer that shows the current reading, it keeps a history for review. LoggFi connected loggers send readings to a cloud dashboard for remote monitoring when a network connection is available.
Explore LoggFi models from Bagmo Private Limited in Kochi, Kerala, for facilities across India.
Compare temperature data logger models
Start with your application and connection. These display models are a starting shortlist; compact, GSM, and local-siren alternatives are available in the complete catalogue.
Scroll the comparison table horizontally to see all specifications.
| Model | Connection | Probe range | Listed temperature accuracy | Offline readings |
|---|---|---|---|---|
| WTD102 | WiFi | −40°C to +50°C | ±0.5°C | 2,000 |
| SMD102 | GSM/GPRS (2G) | −40°C to +50°C | ±0.5°C | 500 |
| WTD102PT | WiFi | −200°C to +400°C | ±0.5°C | 2,000 |
| WTD102HM | WiFi | −40°C to +50°C | ±0.5°C | 2,000 |
Listed accuracy must be confirmed at your working temperatures. Probe range is separate from the electronics’ operating limits; offline storage requires power. Model details and quotation links follow below.

WiFi · OLED display
WTD102
Refrigerators and cold rooms with facility WiFi
An NTC temperature logger with an OLED display for fixed monitoring points with suitable wireless coverage.
- Probe range
- −40°C to +50°C
- Listed temperature accuracy
- ±0.5°C
- Sensor
- NTC
- Offline capacity
- 2,000 readings

GSM · OLED display
SMD102
Temperature monitoring where WiFi is unavailable
An NTC temperature logger with an OLED display and a SIM-based connection. Confirm compatible GSM/GPRS (2G) service on site.
- Probe range
- −40°C to +50°C
- Listed temperature accuracy
- ±0.5°C
- Sensor
- NTC
- Offline capacity
- 500 readings

WiFi · OLED display
WTD102PT
Processes that need a wider probe temperature range
A WiFi PT100 model with an OLED display. Select the probe assembly for the temperature, mounting and conditions of your process.
- Probe range
- −200°C to +400°C
- Listed temperature accuracy
- ±0.5°C
- Sensor
- PT-100
- Offline capacity
- 2,000 readings

WiFi · OLED display
WTD102HM
Rooms that need temperature and humidity records
A WiFi model with an OLED display and NTC / SHT20 sensing. The catalogue lists 0–90% RH; request humidity accuracy separately.
- Probe range
- −40°C to +50°C
- Listed temperature accuracy
- ±0.5°C
- Sensor
- NTC & SHT20
- Offline capacity
- 2,000 readings
Specifications are from the LoggFi catalogue. Probe range is separate from the electronics’ operating limits. Confirm accuracy at your working temperatures, the supplied probe and calibration scope. Offline recording requires power; capacity is not battery runtime.
Choose calibration and service with your logger
The catalogue lists internal / NABL calibration options. Tell us your required calibration points and certificate requirements so the quotation can identify the supplied device and probe, certificate scope and calibration charges.
Pricing is configuration-specific. Ask for hardware, calibration, installation, cloud access, alert charges and renewals as separate line items, including taxes and written warranty terms.
How real-time temperature monitoring works
A connected data logger lets your team review readings remotely as they reach the cloud. To choose a real-time data logger, compare the recording interval, upload frequency and alert delivery time separately.
Record a reading
The probe measures temperature and the logger records readings at the configured logging interval.
Upload through the network
The logger sends readings through facility WiFi or a compatible SIM-based GSM connection.
Review the dashboard
Your team views uploaded readings and temperature history through the cloud platform. Check the reading timestamp when assessing current conditions.
Receive a configured alert
Remote notifications help the responsible person respond to an out-of-range condition. Delivery depends on connectivity and the configured alert service.
How quickly will I see a reading or alert?
- Recording interval
- Catalogue setting: 1 – 40 minutes. This describes recording frequency, not a guaranteed dashboard refresh or alert time.
- Upload frequency
- Confirm the upload configuration for your chosen model. A measured end-to-end upload time is not published here.
- Alert delivery
- Ask for a demonstration with your thresholds, recipients and notification channels. No measured delivery-time guarantee is published here.
What happens when the connection fails?
Listed WiFi temperature models store up to 2,000 offline readings; GSM temperature models store up to 500 while powered. New cloud readings and remote temperature alerts need a working connection. A last uploaded reading cannot establish the current temperature during an outage.
Before commissioning, confirm the full-buffer policy, how stored readings upload after reconnection, and any local alarm operation. Test power backup separately from network recovery.
Estimate offline storage durationWhat to check in a monitoring demonstration
Ask the team to record the time of a controlled temperature change, the corresponding reading timestamp, when it appears in the dashboard, and when each recipient receives the alert. Repeat a network-disconnection and recovery test. Use these observed results to agree the setup your facility needs.
What is the best temperature data logger for your application?
The best fit meets your required measurement range and accuracy, has calibration evidence at the temperatures you use, and can record and alert reliably at your installation. Choose WiFi where facility internet is dependable, or a compatible GSM logger where you need a connection independent of WiFi. Then compare outage handling and the full cost of ownership.
This LoggFi selection guide compares our configurations using the published catalogue. It is not a ranking based on independent tests of competing brands. Request a demonstration and the supplied model's specification before ordering.
Laboratory refrigerator or cold room
Temperature monitoring within the NTC range. Catalogue range: −40°C to +50°C; listed temperature accuracy: ±0.5°C.
Confirm accuracy and calibration at your actual storage temperatures, probe placement and closed-door signal coverage.
A process outside the NTC temperature range
A PT100 probe selected for the process. Catalogue range: −200°C to +400°C; listed temperature accuracy: ±0.5°C.
Specify the complete probe assembly, cable, immersion depth and calibration points. Mount the electronics within their separate operating limits.
A room that needs temperature and humidity records
Combined temperature and relative-humidity monitoring. Catalogue range: −40°C to +50°C; listed temperature accuracy: ±0.5°C.
Request the humidity accuracy and calibration specification; a humidity range alone does not establish accuracy.
A site needing an audible local warning
A temperature logger with a local siren option. Catalogue range: −40°C to +50°C; listed temperature accuracy: ±0.5°C.
Confirm siren operation, power requirements and alert behaviour during a network outage in a site demonstration.
Scroll the table horizontally to compare both connections.
| Decision | WiFi models | GSM models |
|---|---|---|
| Connection | Facility WiFi and working internet; confirm band and authentication support | SIM-based GSM/GPRS (2G); confirm compatible operator service at the site |
| Offline capacity | 2,000 readings | 500 readings |
| Storage at 5-minute intervals | Approximately 166.7 hours | Approximately 41.7 hours |
| Recurring connectivity costs | Existing internet and any network maintenance | SIM activation, data plan and renewals |
| Remote alerts during a network outage | Depend on restoring connectivity; confirm local alarm options | Depend on cellular connectivity; confirm local alarm options |
| Before ordering | Test the actual installation with the IT team | Test a compatible SIM in the logger at the installation |
Storage examples assume an empty buffer, continuous power and one reading per interval. They do not describe battery life. The catalogue lists typical battery backup of 20–30 hours.
Compare the complete quotation, including warranty
Compare hardware and probes, installation, calibration and recalibration, cloud access, retention and exports, alert charges, SIM/data where needed, taxes and service. Agree the period you want to compare, such as three years, and ask every supplier to itemise the same items. Published model information does not include a fixed price or warranty duration; request written warranty terms, exclusions and repair arrangements with your quote.
Get help choosing a temperature loggerWiFi or GSM: which connection fits?
Choose a connected temperature logger when your team needs to review readings remotely while monitoring continues. A standalone USB logger may suit a job where someone retrieves the device and downloads its stored record afterward. Compare the required reporting workflow before choosing the connection.
WiFi data logger
For fixed monitoring points with reliable facility WiFi and internet access. LoggFi WiFi temperature models store 2,000 offline readings. Check coverage beside the equipment and agree network access with your IT team.
View WiFi models and specificationsGSM data logger
For installations that need a SIM-based connection independent of facility WiFi. LoggFi GSM temperature models store 500 offline readings. The listed devices use GSM/GPRS (2G); verify operator coverage and service before purchase.
View GSM models and specificationsThe LoggFi models on this page use WiFi or GSM for cloud connectivity. The catalogue’s 5V USB specification describes power input / charging; it does not establish USB data export or automatic PDF reporting.
Choose the sensor for your temperature range
| Logger family | Sensor | Temperature range | Listed accuracy |
|---|---|---|---|
| LoggFi | NTC | −40°C to +50°C | ±0.5°C |
| LoggFi+ PT100 | PT-100 | −200°C to +400°C | ±0.5°C |
| LoggFi Hygro | NTC & SHT20 | −40°C to +50°C | ±0.5°C |
Hygro adds humidity monitoring from 0–90% RH. A wider probe range does not mean the logger electronics can operate at those temperatures: the catalogue lists an electronics operating environment of 10–40°C and 30–70% RH. Confirm probe suitability, placement and accuracy at your actual working temperatures.
Match the installation to the application
- Cold rooms and food storage
- Check the full storage temperature range, door-opening patterns and connectivity around insulated walls. Choose probe positions that represent the stock being monitored.
- Hospitals, laboratories and blood storage
- Define the equipment’s required limits, escalation contacts and record-retention needs. Specify calibration points and documentation with the team responsible for quality.
- Pharmaceutical warehouses
- Decide whether temperature alone or temperature and humidity must be monitored. Use the facility’s mapping and procedures to determine how many monitoring points are needed.
- Industrial and low-temperature monitoring
- Consider a PT100 model when the NTC range does not cover the process. Confirm the probe assembly and installation are suitable for the intended conditions.
Logging intervals, outages and alerts
The catalogue lists configurable logging intervals from 1 to 40 minutes. At a five-minute interval, 2,000 readings cover approximately 6.9 days, while 500 readings cover approximately 41.7 hours. These figures describe storage capacity, assuming the device remains powered; they are not battery-runtime figures.
Typical battery backup is listed as 20–30 hours. Remote notifications depend on connectivity, power and the configured service. Confirm what happens during an outage, how stored readings are uploaded afterward and whether an on-site siren is needed.
Offline storage calculator
Estimate how much time the listed LoggFi temperature logger memory covers at your logging interval. This assumes an empty buffer, continuous power and one stored reading per interval.
Enter a whole number from 1 to 40.
166.7 hours (approximately 6.9 days)
2,000 readings × 5 minutes ÷ 60 = storage duration in hours.
Storage capacity does not extend battery life. The catalogue lists typical battery backup of 20–30 hours. Cloud updates and remote alerts need a connection; confirm overwrite and reconnection behaviour for the supplied model.
Unlimited cloud storage for up to 3 years
LoggFi stores an unlimited number of uploaded temperature readings in the cloud for up to three years. Your team can review the temperature history of each monitored refrigerator, freezer or cold room, whether it uses a WiFi data logger or a GSM data logger.
When investigating a temperature change, you can check when the first reading crossed the configured limit, how high or low the recorded temperature went, and when readings returned to the required range.
Cloud history retained for
Up to 3 years
Unlimited uploaded readings for each monitored location.
Temperature and device-offline notifications
What triggers an alert?
High temperature
The data logger records a temperature above the upper limit set for the equipment.
Low temperature
The data logger records a temperature below the lower limit set for the equipment.
Device offline
The logger stops sending readings to the cloud. This alerts staff to check the logger’s power and WiFi or GSM connection and verify the current equipment temperature on site.
How does your team receive notifications?
Choose the channels that suit the people responsible for each location and shift.
Phone call
Draw the on-duty operator’s attention to an urgent alert, including after hours.
WhatsApp
Deliver an alert directly to the designated contact on WhatsApp.
SMS
Send a text alert to the responsible staff member’s mobile number.
Email
Send an alert to a supervisor’s inbox or a shared quality-team mailbox.
Mobile app notification
Prompt staff to open the LoggFi app and check the latest uploaded reading for the affected equipment.
Who responds at each level?
A facility can use the following alert escalation hierarchy to assign responsibility across shifts.
Scroll the table horizontally to see each role and response.
| Level | Responsible person | When and how to respond |
|---|---|---|
| 1. Initial response | On-duty operator | Check the equipment when the alert arrives. Verify the temperature on site and investigate the cause. |
| 2. Escalation | Shift supervisor | Follow up if the operator is unavailable or the issue continues beyond the facility’s agreed response time. Coordinate with maintenance or IT as needed. |
| 3. Incident review | Quality manager or facility head | Review prolonged or repeated incidents, assess the impact on stored material and document the action taken. |
Check temperature readings from anywhere with the LoggFi mobile app
The LoggFi mobile app lets your team check the latest uploaded temperature and review earlier readings from anywhere with an internet connection.
Example: an overnight freezer alert
For example, if a freezer sends a high-temperature alert overnight, the shift supervisor can open the app, check the time and value of the latest reading, and review how the temperature changed. After the on-site team responds, the supervisor can check subsequent readings to see whether the freezer has returned to its required range. If the logger is offline, the timestamp shows when it last reported.
What to include in a quotation request
- Facility location in India, equipment type and number of monitoring points.
- Required temperature range, humidity needs and probe placement.
- WiFi access or compatible GSM service at each location.
- Display, local alarm, remote alert recipients and reporting requirements.
- Calibration points, certificate requirements and installation support.
Ask for hardware, cloud service, SIM/data, calibration, installation and taxes to be itemised. The catalogue lists internal / NABL calibration options; confirm the certificate and scope supplied with your order.